358 ExtremeWare Error Message Decoder
Error Messages
Error Reading Register
ERROR: Slot 1 port xx register 8a not ready after select
Software Version
ExtremeWare 6.2 and later
Hardware Version
BlackDiamond, Summit “i” series
Explanation
Timeout occurred while the ASIC tried to read a register on slot 1 on port xx. May be the card is not
active.
The switch will take the action configured using
sys-health-check. If you have configured
sys-health-check to shut down the card, the card is set to non-operational.
Action
Run diagnostics to get details on the hardware. If the problem persists, contact Technical Support.