Extreme Networks ExtremeWare Version 7.8 Specifiche Pagina 650

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 978
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 649
650 ExtremeWare Error Message Decoder
Warning Messages
Port Not in VLAN
<WARN:EAPS> eaps_runtime.c 1222: Warning! Port (1:1) not in vlan "v1"
Software Version
ExtremeWare 6.2.2 or later
Hardware Version
All
Explanation
This message indicates that the port selected to send out the EAPS PDU has not been added to the
control VLAN. The PDU cannot be sent.
Action
Configure the EAPS control VLAN correctly by adding both the ring-ports to it as tagged ports.
Vedere la pagina 649
1 2 ... 645 646 647 648 649 650 651 652 653 654 655 ... 977 978

Commenti su questo manuale

Nessun commento