760 ExtremeWare Error Message Decoder
Warning Messages
EAPS: Port Not Added For Protected VLAN
EAPS: Protected vlan u93 does not have port 4:2 added to it
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
This message indicates that the EAPS domain has the information about a port on the bridge; but the
port has already been removed from the bridge.
Action
1 Check whether user has removed the port from the bridge.
2 Disable and enable the EAPS domain again.