492 ExtremeWare Error Message Decoder
Error Messages
Adding Bridge Interface for Segment Port Failed
EAPS Shared-port 1:1 - Cannot add bridge interface for segment port 2:1. Segment
interface value is NULL
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
This message indicates that the ESD (EAPS super domain) does not have the interface for the segment
port.
Action
Delete the port from EAPS and add it again.
If the problem appears again, delete and create the shared port ESD.